Environmental Monitoring Station Controllers - 3580 Master Series
Environmental Monitoring Station Controllers - 3580 Series

 

 

FEATURES:

 

  • Manage Multiple Monitoring Sites
  • Local Output Control
  • Allows for Staggering Reports
  • Simultaneously Operate as a Repeater

 


 

DESCRIPTION:

The Environmental Monitoring Station Controllers - 3580 Master Series were designed to monitor environmental sensors and send control signals to an advanced warning system. Conditions like water level, visibility, wind speed, or road temperature can be monitored by an Environmental Monitoring Station Controller which can send a control signal to a remote warning system to alert the public to an emergency condition. Alternatively the Environmental Monitoring Station Controllers can locally control a system using its control outputs.

The Environmental Monitoring Station Controller includes a Hydromet Data Logger/Controller - Model 3512-00, a Solar Panel Voltage Regulator - Model 5310-00, a Data Transceiver - Model 3701-00, and a Lightning Protection Device - Model 7200-00. The Environmental Monitoring Station Controller allows you to assign up to three inputs to each of four output channels to control the public warning system. The Data Transceiver is a VHF radio which provides the Environmental Monitoring Station Controller with outstanding resistance to signal interference caused by rain giving you more reliable performance during inclement weather events. The Solar Panel Voltage Regulator is intended for float charging lead acid batteries.

A typical application for the Environmental Monitoring Station Controller is as an Advance Warning System to advise motorists of a flooded or impaired roadway. While the Environmental Monitoring Station Controllers can be use independently they are often part of an integrated system consisting of the master monitoring station, a base station, and multiple warning sites. For example, with the flooded roadway a monitoring site with a water level sensor attached to the Environmental Monitoring Station Controller would be set up at the point where the road floods and two or more remote warning stations would be located at a point where vehicles could turn around or take an alternate route. Meanwhile the water level data from the Environmental Monitoring Station Controller and the information that the warning systems have triggered is sent to a base station monitored by an agency like the emergency management team or transportation department.

The Environmental Monitoring Station Controller can send timed reports, event generated reports, and command generated status reports. The Environmental Monitoring Station Controller reports can either pass through an optional repeater station or are received directly at the central site base station. Each Environmental Monitoring Station Controller can be used as a repeater for important last-mile connectivity. If you need the Environmental Monitoring Station Controller to be a repeater or have remote capability, the Flashing Beacon Controller with Maximum Power Point Tracking Load Control Charger is a good choice.


 

SPECIFICATIONS:
Refer to individual Environmental Monitoring Station Controller components for specifications

Inputs ...........................   Varies depending on model
Outputs ...........................   Varies depending on model
Operating Voltage ...........................   12 to 18 VDC
Current Draw ...........................   < 55 mA + current draw of flashing beacons
Battery Cable ...........................   5 ft (1.52 m)
Radio Cable ...........................   2 ft (0.61 m)
Antenna Cable ...........................   8 in (20.3 cm)
Dimensions ...........................   12x14x5.5 in (30.5x35.6x14 cm)
Shipping Weight ...........................   9 lbs (4.1 kg)


For specifications on Environmental Monitoring Station Controller Data Logger/Controller click HERE.
For specifications on Environmental Monitoring Station Controller Solar Panel Voltage Regulator click HERE.
For specifications on Environmental Monitoring Station Controller Data Transceiver click HERE.
For specifications on Environmental Monitoring Station Controller Lightning Protection Device click HERE.


 

ORDERING GUIDE:
HSE Warranty
General Terms and Conditions

Environmental Monitoring Station Controllers

Model 3580-31 ......... Environmental Monitoring Station Controller, Dual Pressure Transducers and Dual Relays; Includes: Data Logger/Controller - Model 3512-00, Solar Charger - Model 5310-00, Lighting Protection - Model 7200-00, and VHF Data Transceiver - Model 3701-00. Relays sold separately.
Model 3580-33 ......... Environmental Monitoring Station Controller, Pressure Transducer and Dual Float Switches; Includes: Data Logger/Controller - Model 3512-00, Solar Charger - Model 5310-00, Lighting Protection - Model 7200-00, and VHF Data Transceiver - Model 3701-00. Relays sold separately.
Model 3580-35 ......... Environmental Monitoring Station Controller, Dual Pressure Transducers with a SCADA Interface; Includes: Data Logger/Controller - Model 3512-00, Solar Charger - Model 5310-00, Lighting Protection - Model 7200-00, and VHF Data Transceiver - Model 3701-00. Relays sold separately.
Model 3580-37 ......... Environmental Monitoring Station Controller, Pressure Transducer, Dual Float Switches, and Barrier Gate Operator System; Includes: Data Logger/Controller - Model 3512-00, Solar Charger - Model 5310-00, Lighting Protection - Model 7200-00, and VHF Data Transceiver - Model 3701-00. Relays sold separately.
Model 3580-51 ......... Environmental Monitoring Station Controller, Dual Pressure Transducers with Cell Modem; Includes: Data Logger/Controller - Model 3512-00, Solar Charger - Model 5310-00, Lighting Protection - Model 7200-00, and VHF Data Transceiver - Model 3701-00. Relays sold separately.

 

RELATED PRODUCTS:

3580 Remote Series ......... Flashing Beacon Controllers
Model 3482-02 ......... Roadway Advance Flood Warning System
Model 5950-01 ......... Telemetry Cabinet


 

SUPPORT: